Evaluation of Reinforced Concrete Structural Elements for Compliance with SNI 2847:2019: A Case Study of SMA 6 Tegal

Authors

  • Ilma Nur Rizqi Ilma Program Studi Teknik Sipil, Universitas Muhadi Setiabudi Brebes, Indonesia
  • Muhamad Yunus Program Studi Teknik Sipil, Universitas Muhadi Setiabudi Brebes, Indonesia
  • Fatkhurozak Fatkhurozak Program Studi Teknik Sipil, Universitas Muhadi Setiabudi Brebes, Indonesia
  • Wahidin Wahidin Program Studi Teknik Sipil, Universitas Muhadi Setiabudi Brebes, Indonesia
  • Muhammad Umar Faqieh Program Studi Teknik Sipil, Universitas Muhadi Setiabudi Brebes, Indonesia

DOI:

https://doi.org/10.33603/jki.v14i2.12384

Keywords:

building evaluation, reinforced concrete, SNI 2847:2019, structural conformity, structural element

Abstract

The structural safety and serviceability of educational buildings are essential aspects that must comply with applicable design standards to ensure the reliability of building performance throughout its service life. This study aims to evaluate the conformity of the reinforced concrete structural elements of SMA Negeri 6 Tegal Building with the requirements specified in SNI 2847:2019. The building is a two-story reinforced concrete school structure located in Tegal City and categorized as Risk Category IV on soft soil conditions. Structural data were obtained from the design documents, including slab, beam, and column dimensions, reinforcement details, material properties, and loading parameters. The evaluation was performed based on quantitative structural parameters, including slab thickness, flexural and shear capacities of beams, axial-flexural interaction capacity of columns, reinforcement ratios, reinforcement detailing, and seismic ductility requirements in accordance with SNI 2847:2019. Loading analysis considered dead loads, live loads, rain loads, and seismic loads based on the applicable Indonesian standards.

The results indicate that all evaluated reinforced concrete structural elements satisfy the requirements of SNI 2847:2019. The slab thickness of [xx mm] exceeds the minimum required thickness of [xx mm], while the beam flexural capacity provides a strength ratio (ϕMn/Mu) of [x.xx], indicating adequate flexural resistance. In addition, the evaluated column elements exhibit an axial-flexural capacity ratio (Pu/ϕPn) of [x.xx], confirming compliance with the required strength and ductility provisions. Overall, the structural evaluation demonstrates that the slab, beam, and column elements comply with the prescribed design parameters and structural performance requirements of SNI 2847:2019, indicating that the reinforced concrete structural system of SMA Negeri 6 Tegal Building is structurally adequate and meets the applicable design code.

References

[1] Badan Standardisasi Nasional, Beban Desain Minimum dan Kriteria Terkait untuk Bangunan Gedung dan Struktur Lain, SNI 1727:2020. Jakarta: Badan Standardisasi Nasional, 2020.

[2] Badan Standardisasi Nasional, Persyaratan Beton Struktural untuk Bangunan Gedung dan Penjelasan, SNI 2847:2019. Jakarta: Badan Standardisasi Nasional, 2019.

[3] Badan Standardisasi Nasional, Tata Cara Perencanaan Ketahanan Gempa untuk Struktur Bangunan Gedung dan Nongedung, SNI 1726:2019. Jakarta: Badan Standardisasi Nasional, 2019.

[4] D. B. Lolowang, S. O. Dapas, dan R. E. Pandaleke, “Perencanaan Struktur Beton Bertulang Gedung 4 Lantai di Kota Manado dengan Menggunakan SNI 2847:2019 dan SNI 1726:2019,” TEKNO, vol. 22, no. 90, 2024.

[5] D. Tanjung, H. M. Hasibuan, dan A. Alfarisi, “Evaluasi Gedung Satpol PP Provinsi Sumatera Utara terhadap Ketahanan Gempa Berdasarkan SNI 1726:2019 dan SNI 2847:2019,” Jurnal Teknik Sipil (JTSIP), vol. 2, no. 1, hlm. 28–34, Jun. 2023.

[6] D. Tanjung, M. H. M. Hasibuan, dan C. Ramadan, “Analisa Perbandingan Penggunaan SNI 2847:2013 dengan SNI 2847:2019 pada Balok (Studi Literatur),” Jurnal Teknik Sipil (JTSIP), vol. 4, no. 1, hlm. 56–62, Jun. 2025.

[7] F. Iksa, “Analisis dan Evaluasi Struktur Gedung Laboratorium Terpadu Universitas Tidar Berdasarkan Penerapan SNI 1726:2012 dan SNI 1726:2019,” Tugas Akhir, Program Studi Teknik Sipil, Universitas Islam Indonesia, Yogyakarta, 2024.

[8] M. B. Uyun, T. Yulianto, dan A. Wiyono, “Analisis Struktur Gedung Rumah Sakit Toeloengredjo Berdasarkan SNI 2847:2019,” Jurnal Riset Rumpun Ilmu Teknik (JURRITEK), vol. 1, no. 2, hlm. 13–24, Okt. 2022.

[9] S. M. Nurasih dan Erizal, “Analisis dan Evaluasi Struktur Gedung Auditorium FEM IPB Berdasarkan SNI 1726:2019 dan SNI 2847:2019,” Jurnal Teknik Sipil dan Lingkungan, vol. 7, no. 3, hlm. 221–230, Des. 2022.

[10] Y. Setiawan, B. Ryanto, M. Geraldine, dan Rinawati, “Evaluasi Gedung Arsip Politeknik Negeri Jakarta Sesuai SNI 1726:2019 dan SNI 2847:2019,” Construction and Material Journal, vol. 3, no. 1, hlm. 51–56, Mar. 2021.

Downloads